Note: For KEPServer v5.3 or higher, refer to 494480 – KEPServer Enterprise v5.3 does not use default.pfe
#KEPWARE CLIENT SOFTWARE#
#KEPWARE CLIENT PC#
Load KEPServer Enterprise software on the PC that has FactoryTalk View ME Studio installed. Refer to 33968 – KEPServer Enterprise version compatibility with PanelView Plus Note: Make sure the version of KEPServer Enterprise is compatible with your PanelView Plus firmware.Refer to 30964 – Upgrading Firmware on a PanelView Plus Terminal.
#KEPWARE CLIENT UPDATE#
If you are using a PanelView Plus terminal, or a PanelView Plus 6 terminal that is 6.10.09 or lower, then you must flash firmware to load the KEPServer driver(s) you require. The actual driver selection would be part of the firmware update process.Reboot the terminal after the services restart.You will be prompted for Services to be restarted, click Yes.Close this window by clicking OK, for your changes to be saved.
#KEPWARE CLIENT DRIVERS#
![kepware client kepware client](https://i1.wp.com/iot.do/wp-content/uploads/sites/2/2016/05/361239-1.jpg)
Go to Start –> Settings –> Control Panel.Exit to the Windows CE desktop – See 249734 – PanelView Plus 6 and PanelView Plus 7: Enabling Desktop Access.For a PanelView Plus 6 terminal running version 6.10.17 or greater or a PanelView Plus 7, there is a Windows CE Control Panel applet called Server Config that will allow you to enable a driver.Depending on the firmware version on you PanelView plus terminal, you will need to perform one of the following:.Setting up the KEPServer Enterprise on a PanelView Plus terminal If connection to an OPC server running on a PC is required, use FactoryTalk View ME Station running on a computer. It communicates directly with the 3rd party devices using Kepware drivers. Note: PanelView Plus terminals running kepware drivers will not communicate with OPC servers running on a PC.
#KEPWARE CLIENT INSTALL#
How do I install a Kepware driver on my PanelView Plus Terminal?.What are the basic steps for setting up KEPServer communications from FactoryTalk View ME Station?.